Ann Nucl Med ; 28(7): 646-55, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24878888

RESUMO

OBJECTIVE: Since myocardial perfusion imaging (MPI) with conventional sodium iodine (NaI) device has low spatial resolution, there have been some cases in which small structures such as non-transmural myocardial infarction could not be properly detected. The purpose of this study was to evaluate potential usefulness of cadmium-telluride (CdTe) semiconductor detector-based high spatial resolution gamma cameras in detecting myocardial infarction sites, especially non-transmural infarction. METHODS: A total of 38 patients (mean age ± SD: 64 ± 21 year) who were clinically diagnosed with acute myocardial infarction were included. Twenty-eight cases of them were with ST segment elevation myocardial infarction (STEMI) and 10 cases with non-ST segment elevation myocardial infarction (NSTEMI). In all patients, myocardial perfusion single photon emission computed tomography images were acquired with Infinia (NaI device) and R1-M (CdTe device), and the images were compared concerning the detectability of acute myocardial infarction sites. RESULTS: The detection rates of the myocardial infarction site in cases with STEMI were 100% both by NaI and CdTe images. In cases with NSTEMI, detection rate by NaI images was 50%, while that of CdTe images was 100% (p = 0.033). The summed rest score (SRS) value derived from CdTe images was significantly higher than that from NaI images in cases with STEMI [NaI images: 12 (7-18) versus CdTe images: 14 (9-20)] (p < 0.001). SRS derived from CdTe images was significantly higher than that derived from NaI images in cases with NSTEMI [NaI images: 2 (0-5) versus CdTe images: 6 (6-8)] (p = 0.006). CONCLUSIONS: These results indicate that MPI using CdTe-semiconductor device will provide a much more accurate assessment of acute myocardial infarction in comparison to current methods.


Assuntos
Compostos de Cádmio , Câmaras gama , Infarto do Miocárdio/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/instrumentação , Semicondutores , Telúrio , Doença Aguda , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único
2.
Ann Nucl Med ; 24(4): 301-11, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20213339

RESUMO

OBJECTIVE: We have developed a prototype gamma camera system (R1-M) using a cadmium telluride (CdTe) detector panel and evaluated the basic performance and the spectral stability. METHOD: The CdTe panel consists of 5-mm-thick crystals. The field of view is 134 x 268 mm comprising 18,432 pixels with a pixel pitch of 1.4 mm. Replaceable small CdTe modules are mounted on to the circuit board by dedicated zero insertion force connectors. To make the readout circuit compact, the matrix read out is processed by dedicated ASICs. The panel is equipped with a cold-air cooling system. The temperature and humidity in the panel were kept at 20 degrees C and below 70% relative humidity. CdTe polarization was suppressed by the bias refresh technique to stabilize the detector. We also produced three dedicated square pixel-matched collimators: LEGP (20 mm-thick), LEHR (27 mm-thick), and LEUHR (35 mm-thick). We evaluated their basic performance (energy resolution, system resolution, and sensitivity) and the spectral stability in terms of short-term (several hours of continuous acquisition) and long-term (infrequent measurements over more than a year) activity. RESULTS: The intrinsic energy resolution (FWHM) acquired with Tc-99m (140.5 keV) was 6.6%. The spatial resolutions (FWHM at a distance of 100 mm) with LEGP, LEHR, and LEUHR collimators were 5.7, 4.9, and 4.2 mm, and the sensitivities were 71, 39, and 23 cps/MBq, respectively. The energy peak position and the intrinsic energy resolution after several hours of operation were nearly the same as the values a few minutes after the system was powered on; the variation of the peak position was <0.2%, and that of the resolution was about 0.3%. Infrequent measurements conducted over a year showed that the variations of the energy peak position and the intrinsic energy resolution of the system were at a similar level to those described above. CONCLUSION: The basic performance of the CdTe-gamma camera system was evaluated, and its stability was verified. It was shown that the camera could be operated daily for several months without calibration.


Assuntos
Compostos de Cádmio , Cintilografia/métodos , Telúrio , Encéfalo/diagnóstico por imagem , Temperatura Baixa , Temperatura Alta , Modelos Lineares , Imagens de Fantasmas , Cintilografia/instrumentação , Fatores de Tempo
3.
Brain Cogn ; 61(2): 189-94, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16466836

RESUMO

A newly developed quantitative near-infrared spectroscopy (NIRS) system was used to measure changes in cortical hemoglobin oxygenation during the Verbal Fluency Task in 32 healthy controls, 15 subjects with mild cognitive impairment (MCI), and 15 patients with Alzheimer's disease (AD). The amplitude of changes in the waveform, which was quantitatively calculated by a signal processing method, was significantly lower in the frontal, and the bilateral parietal areas in the AD group, whereas that in the MCI group was significantly lower only in the right parietal area. The NIRS system may be a potential tool for the primary screening of AD.


Assuntos
Doença de Alzheimer , Encéfalo/metabolismo , Encéfalo/fisiopatologia , Hemoglobinas/metabolismo , Modelos Biológicos , Oxigênio/metabolismo , Espectrofotometria Infravermelho/métodos , Doença de Alzheimer/epidemiologia , Doença de Alzheimer/metabolismo , Doença de Alzheimer/fisiopatologia , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/epidemiologia , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Comportamento Verbal